Bd facscanto ii clinical software solutions

As a leading provider of tools for flow cytometry, bd biosciences is committed to offering comprehensive, innovative software solutions, including thirdparty. Each sale of a stored unit of this software grants the purchaser a nontransferable, nonexclusive, personal. Flow fluid cyto cell metry measurement a variety of measurements are made on cells, cell organelles, and other objects suspended in a liquid and flowing at rates of several thousands per secondthrough a flow chamber. Not for use in diagnostic or therapeutic procedures. Provides streamlined software workflows for acquisition and analysis. Updated for 6color reagent and bd facscanto clinical software v2. Absolute lymphocyte counts were determined by bd facscanto ii flow cytometer using bd facscanto clinical software v2. Instruments available for use at the flow cytometry core facility, institute of cell and molecular science, barts and the london, queen mary, university of london. Seven and eightcolor immunophenotyping on this device require validation by the user. Bd biosciences recommends that firsttime users of this cytometer take advantage of operator training offered with the. The facscanto ii offers unbeatable consistency and optimal signal detection with increased resolution and sensitivity for multicolor assays.

Built on more than 25 years of bd experience and leadership in flow cytometry and multicolor analysis, the bd facscanto ii system is an easytouse benchtop analyzer that delivers proven performance, accuracy, and highquality results. Bdx, a leading global medical technology company, today provided an update on a previously announced voluntary recall of the bd alaris system regarding software for the pc unit and certain modules. See headers and footers on page 100 in the bd facsdiva software reference manual. Daily routine procedures such as startup, shutdown, and cleaning routine cycles are automated as a result of fluidic integration with bd facscanto clinical software or bd facsdiva software. Page 1 bd facscanto ii instructions for use for in vitro diagnostic use part no.

Bd facscanto clinical software includes specific application modules optimized for use with specific ivd reagent kits. Crossinstrument and crosssite standardization using bd facsdiva software s custom application settings. It provides a high degree of automation and quality control to reduce hands on time for technicians and improve reliability of results. A june 2007 bd biosciences benex limited canada japan bay k 1 ad nippon becton dickinson 2350 qume drive toll free 888 2590187 company, ltd. All other cytometer and fluidics cart functions are controlled by bd facscanto clinical software and bd facsdiva software provided with the instrument. Facscanto ii standard operation protocol basic operation. By working in close collaboration with customers, bd can help enhance outcomes, lower costs, increase efficiencies, improve safety and expand access to healthcare. Multisite evaluation of the bd stem cell enumeration kit for. These panels feature automated gating, calculations, and report generation to deliver consistent, reproducible, and standardized analysis. The bd facscanto system breaks new frontiers in flow cytometry by providing an efficient, easytouse yet powerful sixcolor benchtop analyzer.

Monitoring hiv identification and enumeration of lymphocyte subsets the bd multitest 6color tbnk kit is the first and only 6color in vitro diagnostic application to provide a complete immune panel in a single tube, saving valuable time and resources. As a leading provider of tools for flow cytometry, bd biosciences is committed to offering comprehensive, innovative software solutions, including thirdparty solutions that support applicationspecific customer requirements. The bd biosciences webinar series is an ongoing, informative program in which senior scientists, professionals in the community, and clinicians present online seminars covering a. Bd facs canto ii users guide barcode flow cytometry. Follow only those sections that apply to the software you are running. Bd facscanto ii flow cytometer reference manual alfresco. Bd facscanto ii resources cell analyzer research instrument. Bd facs canto ii operators manual marshall scientific issuu. New worksheet features create headers and footers on the worksheet, including cytometer name, experiment name, user name, date and time, bd facsdiva software version, etc. Accessgudid bd facscanto 00382903389629 bd facscanto ii cytometer 422 sys ivd. It is the responsibility of the buyeruser to ensure that all added electronic files including software and transport media are virus free. Abstract submission deadline approaches messages sorted by. Crossinstrument and crosssite standardization using bd facsdiva softwares custom application settings.

Waste tank is empty and refill the bottom layer of waste tank with bleach. Carousel report now includes the directory selected for. The bd facscanto ii system can optionally be used with the bd facs loader for automatic sample introduction, a standalone barcode reader for data input into bd facscanto clinical software, and with the bd facs sample prep assistant ii for automatic sample preparation of assays utilizing the lysenowash method. The optional bd facscanto ii handheld barcode reader reads twodimensional barcode labels and it is used to read the compensation matrix of the bd facs 7color setup beads reagent into bd facscanto clinical software.

Bd facscanto ii instructions for use manual pdf download. Bd facscanto fluidics with bd facscanto clinical software or bd facsdiva software. At the heart of the cytometer, for example, the fluidics system features a fixedalignment flow cell to minimize startup time and improve reproducibility. Software bd facslink laboratory information system interface solution. With optimal reproducibility, the bd facscanto ii system reduces handson technician time and costs associated with repeat testing. The bd facscanto is often hailed as the new generation of flow cytometry. The bd facscanto ii flow cytometers 422 and 53 configurations function as part of a system with dedicated clinical software intended for use with cleared or approved in. Sit cleaning between tubes is automatic when you use bd facscanto clinical software. The bd facscanto ii system features many innovations. Bd facscanto clinical software can import worklists from bd facs sample prep assistant spa software v2. It automatically sets cytometer detector voltages and creates compensation tables based on a single run with bd facs 7color setup beads.

Bd facscanto ii features bd facscanto ii clinical cell. Bd bioscience facscanto ii flow cytometer marshall scientific. Cytometry bd facscanto ii laser errors next message. In the fluidics system, the sample travels up the sample injection tube, and hydrodynamic focusing within the flow cell forces particles into a singlefile stream where laser light intercepts the stream at the sample interrogation point. Bd biosciences recommends that firsttime users of this cytometer take. Multisite evaluation of the bd stem cell enumeration kit. It includes automated setup and compensation, applicationspecific analysis modules, and predefined reports with integrated quality control. The loader is operated using bd facscanto clinical software and bd facsdiva software. There is enough amount of sheath fluid to perform machine start up and sample acquisition. Make sure the following steps are done before running your samples. The modules feature automated gating, calculations, and report generation to deliver a consistent, reproducible, and standardized analysis.

Bd facscanto clinical software is supplied with the bd facscanto and facscanto ii systems and includes application panels optimized for use with specific ivd reagent kits. Bd facscanto ii flow cytometer quick reference guide this guide contains instructions for both bd facscanto clinical and bd facsdiva software. The bd facscanto ii is a powerful multicolour benchtop analyser offering easy to use, powerful and reliable performance. Interference there are no known incompatibilities with bd facscanto clinical. The bd facscanto ii is designed to address the needs of todays busy clinical lab. Bd facscanto ii system critical security patches for bd influx critical security patches for facsverse lsrfortessa sample prep assistant systems facsymphony a3a5 systems bd pyxis products november 2019 through february 2020 product security patch bd kiestra tlawca octdec 2019. Facscanto clinical software and bd facsdiva software.

It automatically sets cytometer detector voltages and creates compensation tables based on a single run with bd facs 7. Facscanto ii standard operation protocol basic operation 1. Setup on page 1 in the bd facsdiva software reference manual. Bd facscanto ii features bd facscanto ii clinical cell analyzer. Facscanto flow cytometer from bd biocompare product. San jose, ca tuesday, august 04, 2009 bd biosciences, a segment of bd becton, dickinson and company, announced today the u. Bd facscanto ii flow cytometer quick reference guide. Bd bioscience facscanto ii flow cytometer marshall. With the industrys most advanced high throughput plate loader and hotel, the s family of analyzers go headtohead with bd facs canto, bd lsr ii, and bd fortessa at a fraction of the cost and size while offering a superior solution for conventional and high throughput flow cytometry applications. Our bd facscanto ii is a 3 laser red 633nm, blue 488nm and violet 405nm cytometer capable of analyzing up to 8 fluorescence parameters and 2 scatter parameters fsc and ssc. It incorporates many technology advances first developed in the bd lsr ii expandable analyzer and the bd facsaria cell sorter. The bd bioscience facscanto ii flow cytometer is a benchtop analyzer providing reliable and accurate results for experiments with up to 10 parameters. This software is for use only on the bd facscanto and bd facscanto ii. Bd biosciences launches laboratory information system.

Bd facscanto ii flow cytometer and bd facscanto clinical software. Bd biosciences 2350 qume drive san jose, ca 9511807 usa tel 877 232. Bd has notified customers affected by this recall, and there. This software is the property of becton, dickinson and company.

Leftover and delinked specimens n 1032 from clinical flow cytometry testing were analyzed on the bd facscanto ii n 918 and bd facscalibur n 905 in normal and mobilized blood, frozen and thawed bone marrow and leucopheresis and cord blood anticoagulated with citrate phosphate dextrose, anticoagulant citrate dextrosesolution. Bd facsflow sheath fluid, bd facsclean solution, and bd facs. Bd facs shutdown solution prevents salt crystal buildup in fluidics lines and is. Use bd facscanto clinical software for performing cytometer quality control. Bd biosciences delivers software and workstations that are intended for running the cytometers supplied by bd biosciences. March 9, 2020 bd becton, dickinson and company nyse. Saves time, improves reproducibility high performance, innovative system the bd facscanto ii fluidics cart is designed to save time and improve system performance. Bd facscanto clinical software overview features workflow sample data productivity, consistency, and reliability from dedicated clinical software the ivd cleared bd facscanto ii system includes software designed to address the needs of todays busy clinical laboratory. Bd facscanto ii flow cytometer filter guide 1for research use only. Cytometry bd facscanto ii laser errors ed podniesinski flow8775 at sat jan 5 17. Bd serves and supports our customers with full offerings beyond our individual products, enabling integrated solutions across healthcare systems to comprehensively improve care and lower costs. Other software fcs and setup files created within bd facscanto clinical software can be imported into bd facsdiva software v5. The bd facscanto ii fluidics system is designed to streamline work, save time, and improve performance.

1333 637 653 415 61 1497 713 625 870 3 886 1283 685 1367 1066 204 1393 1134 714 944 993 473 1583 1303 227 304 407 1130 471 910 1508 653 496 124 706 817 189 418 71 762 25 1348 581 839 618 686 488 1495 1198 491